Noisy LivoniaPrint.to
Home / Articles / Why Meeting Noise Limits Does Not Mean There Is No Noise Problem
Measurements

Why Meeting Noise Limits Does Not Mean There Is No Noise Problem

A measurement can correctly show that limit values are not exceeded and still fail to describe what people live with every night. Why that happens, and what it means legally.

Published 2026-07-12·4 min read
Why Meeting Noise Limits Does Not Mean There Is No Noise Problem

This is the single most important and most misunderstood point in the whole subject of noise disputes. A company commissions a measurement. An accredited laboratory carries it out. The report states that limit values are not exceeded. And from that a conclusion is drawn: there is no problem, the complaints are unfounded.

That conclusion is wrong — not because the measurement is wrong, but because the measurement answers a different question from the one residents are asking.

Two different questions

The measurement answers: at a specific point, at a specific height, at a specific time, does the equivalent sound level exceed the figure set in the regulation?

The resident asks: can I sleep in my flat at night with the window open?

The answer to the first can be "no, it does not exceed". The answer to the second, at the very same moment, can be "no, I cannot". There is no contradiction here.

Why this happens — six reasons

1. A limit value is not the threshold at which nuisance begins

Limit values are an administrative compromise between environmental protection and economic activity. They are not a medical boundary beyond which noise stops affecting people. World Health Organization recommendations for night noise are lower than the statutory limits in many countries. Compliance means legality, not comfort.

2. The equivalent level averages away exactly what disturbs

Measurements normally use LAeq — the energy-average level over a period. A continuous monotonous hum and the same average level produced by a few passing cars look identical in the measurement. To a human being they are nothing alike: with intermittent noise people habituate and fall asleep in the gaps; with a monotonous one they do not.

3. A-weighting suppresses precisely the low frequencies

Standard A-weighting imitates the sensitivity of the human ear at quiet levels and therefore cuts low frequencies substantially — roughly 30 decibels at 50 Hz. If the source noise is a low-frequency hum, the A-weighted result systematically understates it relative to how a person perceives it indoors.

4. The measurement point is not where people live

Environmental noise measurements are usually taken at ground level, 1.5 metres up, at the property boundary. If a fence and trees stand between source and microphone, they screen that low point. On upper floors that screening does not work — sound arrives directly. A measurement at the fence says nothing about those flats.

5. A measurement is a snapshot

Three days in particular weather conditions is not a year. Low-frequency sound propagation depends heavily on wind direction and air temperature layering. This is exactly why residents so often say "some days you cannot hear it at all, on others it is unbearable" — and exactly why a measurement on particular days can land in favourable conditions.

6. Background means one thing by day and something else at night

By day, industrial noise merges into the traffic background and its contribution may not be detectable at all. At night, when the background subsides, that same unchanged noise becomes the dominant sound in the area. A measurement reporting a single figure for both periods does not capture that shift.

How this looks in a typical case

To make it concrete, take an invented but typical example. Suppose an industrial installation runs continuously next to a residential building, and measurements are taken in all three periods of the day — twice in each, with the installation running and switched off.

PeriodInstallation runningInstallation offDifferenceLimit
Day55 dB(A)55 dB(A)065 dB(A)
Evening52 dB(A)50 dB(A)+260 dB(A)
Night47 dB(A)45 dB(A)+255 dB(A)

Formally the conclusion is unambiguous: no limit is exceeded in any period, and by a comfortable margin. On paper the case is closed.

But look at the table again:

What such a measurement actually proves

Not that there is no noise. But that the installation does produce noise, and that its contribution becomes detectable specifically at night — which is exactly when it disturbs people most.

And if no measurement with the installation switched off was taken in the evening or at night, then nothing at all can be said about those periods.

What follows from this

The measurement result carries real legal weight: if limit values are not exceeded, it is harder for an authority to apply enforcement measures. We understand and accept that.

But it does not follow that there is no problem or that nothing needs to be done. What follows is only that the solution is unlikely to arrive as an official order — it has to be a decision the company takes itself. Which is precisely why the request to install sound insulation is addressed to the company, not only to the authorities.

What this site documents

This article is published by the Jūrkalnes and Irlavas neighbourhood community. We document the industrial noise produced by the outdoor Nestro filter at SIA Livonia Print, Jūrkalnes iela 15/25, Riga. The installation has run 24 hours a day since 2021, and its hum reaches around 12 streets. The residents’ request to the company is a single one: fit an acoustic enclosure around the filter and sound insulation on the air ducts. The board member of SIA Livonia Print is Trond Erik Isaksen, and it is to him that the neighbourhood’s letters about the noise have been addressed.

More on the Livonia Print noise · Home page

Related articles

#11How Accredited Environmental Noise Measurements Work and How to Read a Report

How Accredited Environmental Noise Measurements Work and How to Read a Report

What accreditation means, how measurement points and periods are chosen, what residual noise is, and how to read uncertainty and the tonality correction.

#13A-Weighting and Low Frequencies: Why a Hum Nearly Disappears in Measurements

A-Weighting and Low Frequencies: Why a Hum Nearly Disappears in Measurements

Why standard A-weighting cuts low frequencies by 30 decibels or more, and why a conclusion about low-frequency dominance should not be drawn from A-weighted data.

#14Residual Noise: How to Establish How Much One Installation Contributes

Residual Noise: How to Establish How Much One Installation Contributes

Measuring with the source running and switched off is the only way to separate an installation's noise from the background. How it is done and what ruins the comparison.

PreviousHow Accredited Environmental Noise Measurements Work and How to Read a ReportNextA-Weighting and Low Frequencies: Why a Hum Nearly Disappears in Measurements